Description
Preface
This manual is applicable to the HY-21-AM series optical amplifier which mainly describes the performance characteristics, technical parameters, installation, debugging, common fault processing and so on. In order to ensure the equipment can be installed correctly and safe operation, please read this manual carefully before installation and debugging the equipment so that avoiding the damage to the equipment or injury to the operating person; Please contact us if have any questions .
Technical parameter
Item | Unit | Technical parameter | Remark | |
CATV wavelength | nm | 1535~1565 | Center wavelength 1550nm | |
PON OLT wavelength | nm | 1310/1490 or 1270/1577 |
Customizable | |
CATV Input optical power | dBm | -10dBm ~ +10dBm | suggested value
-5dBm~+10dBm |
|
Max output power | dBm | 38 | 1U rack | |
Optical power stability | dB | ±0.1 | ||
Niose figure | dB | ≤ 6 | @+0dBm Input,λ=1550nm | |
Reflection loss | Input | dB | ≥ 45 | |
Output | dB | ≥ 45 | ||
OSW | Input ports | 2 | ||
Insertion loss | dB | ≤1.0 | ||
Switching time | s | <0.5 | ||
Optical connector type | SC/APC;SC/PC;LC/APC;LC/PC | Customizable | ||
C/N | dB | ≥ 50 | The test conditions are performed by GT/T 184-2002. | |
C/CTB | dB | ≥ 63 | ||
C/CSO | dB | ≥ 63 | ||
Supply voltage | V | AC110V/220V(90V ~ 265V) or
DC48V(38- 58V) |
||
Equipment power consumption | W | < 70 | ||
Working temp range | ℃ | -5 – +42 | ||
Max relative humidity | % | Maximum 95% without condensing | ||
Storage tempe range | ℃ | -30 ~ +70 | ||
Max storage relative humidity | % | Maximum 95% without condensing | ||
Dimensions | mm | 337(W)*482(L)*44(H) | ||
Packing size (1 set) | mm | 487(W)*582(L)*110(H) |